The singlephase distribution transformer consists of a primary winding and a secondary winding wound on a laminated steel core. This category includes inadequate or defective installation, insulation deterioration, and short. Some companies have test fuse tables based on the transformer size and voltage. The risk of a transformer failure is actually twodimensional, the frequency of failure and the severity of failure. Types of transformer different types of transformer. Report on failure of 400220kv33kv, 315mva transformer bhel make at bamnauli substation of delhi transco on 11022008 1. Asset criticality modelling in electricity distribution networks. Transformer installation, operation, and maintenance manual. A potential failure is an identifiable physical condition which indicates a functional failure. Analysis of power transf failure in trans utilities 15. The difference is categorized on the factors like the type of network used, location of installation, usage either for low voltages or high voltages. Simulation of transformer state using weibull distribution the weibull distribution is widely used to reflect the equipment failure rate changes with service age 14.
Transformer causes of failures the fault that most frequently occur in practice may be classified broadly as follows, although to a large extent the different kinds often react upon one another. Eventful transformer failures eventful transformer failures describe a tank failure where the tank is visibly damaged due to an internal fault. I introduction t his paper presents an integrated management system for distribution transformer loading based on the methodology described in the references 1, 2 and 3. The rating plate fixed to the transformer, details the transformer vector group, voltage ratio, kva rating, tapping range, phase orientation, etc.
The premature failure rate of distribution transformers is above 25% in some of the regions of the state of madhya pradesh m. Prediction of remaining life of power transformers based on. What is distribution transformer, electrical isolation. The weibull distribution was applied to model the failure rate, as a function of age, using the method given in standard bs61649. Set the tap changer and insert location pin to lock in desired position, prior to energisation. Actom distribution transformers plays a vital role in the electrical distribution chain. Jongen and others published a statistical approach to processing power transformer failure data find, read and cite all the research you need on researchgate. Actom distribution transformers designs and manufactures a wide range of distribution transformers ranging from 16kva 5000kva.
Instructions for oilimmersed distribution t ransformer s. Furan derivatives test, which uses software application once the oil is eligible for furan test. To track the cause of the failure is the first step to formulate its solution. Asset criticality modelling in electricity distribution networks paul mitchell and simon todd commerce commission. A distribution transformers function is straightforward. Transformer kva rating nema maximum db ratings 09 40 1050 45 51150 50 150 55 301500 60 501700 62 701 64 decibelsunit for measuring the loudness of sound. Management system of distribution transformer loading. International organization of scientific research 43 p a g e the distribution transformer is static equipment and is used to either step down or step up the voltage as the case may be. The basic principle of operation of a transformer is explained in chap. Complete selfprotection technolgy to minimize the failures. The substation is operating with 1260 mva total transformation. Unlike motors and generators, transformers are nearly 100% efficient, operate continuously with no maintenance, and have no moving parts. The risk of a transformer failure is actually twodimensional.
Difference between power transformer and distribution transformer here we will discuss, the difference between power transformer and distribution transformer. Also there is detailed analysis about the consisting of a distribution transformer. The premature failure rate of distribution transformers is above 25% in some of the regions of. Pdf a statistical approach to processing power transformer.
Failure to follow instructions may result in death or serious injury important. Bushes are insulating devices that insulate a high voltage electrical conductor to pass through an earth conductor. Distribution transformer is an electrical isolation transformer which convert highvoltage electricity to lower voltage levels acceptable for use in homes and business. Failure of transformer in power substation is not a sudden phenomenon, for that matter each and every failure will take place only after alerting through some presigns. Difference between power transformer and distribution transformer. In distribution side transformers there are commonly two. It is quite common practice to exceed the nameplate rat ing when loading power and distribution transformers for short times.
Also information about some types of transformers are gathered as well as distribution transformer connections installations. In transformers it provides a current path through the tank wall. For the failures reported, the leading cause of transformer failures is insulation failure. Inside the transformer paper insulators are used which are surrounded by oil that provides further insulation. Transformers convert electric power, to magnetic flux, to electric power in a new form. Determination of probability of failure of power transformers. Among the materials consulted while preparing this book are.
Abstractdistribution transformer is an essential link in the distribution system. In a transformer, the only moving part is the oscillating magnetic flux in the core. As you are aware, the distribution sector has a large number of distribution transformers of several capacities. Practical approach for detection of failure of distribution transformers and their remidies.
This type of transformer is categorized on the basis of a number of turns in the primary and secondary windings and the induced emf. Minimize the failures of distribution transformer seminar. The invention of a practical efficient transformer made ac power distribution feasible. Causes, prevention, and maximum service life introduction over the years, hartford steam boiler has investigated thousands of transformer failures, compiling an extensive database of loss information. The software gives the corresponding reading about the present health of distribution transformer and thus the performance can be known, the output of which gives failure. Investigation into current transformer failures within eskom distribution deepak rampersad in partial fulfilment of the requirements for the degree master of science in power and energy systems, faculty of engineering, university of kwazulunatal december 2010 supervisor. Reasons for transformer failures, distribution transformer.
The damage may cause no significant impact, aside from the need to replace the tank, or it could be catastrophic. Also captured is the impact of distribution losses on upstream facilities, i. Failure investigation consists of many steps in accurate sequence to conclude a significant outcome for transformer failure. The repaired transformer should be despatched only after the inspection is conducted and. Transformer design drytype and cast resin, protection methods are being referred and more also included in the specific research document.
Any failure of these transformers is bound to cause great inconvenience to the consumers and huge financial losses to the utilities. Transformer a has an impedance of 4%, transformer b which is to be parallel to a must have an impedance between the limits of 3. That is, the highest failure rates are in the first few years. Distribution transformer is the key equipment in the distribution power grid, and sampling inspection is the main method used to ensure quality control. Abstract distribution transformer is an essential link in the distribution system. Simplified transformer overloading guide lines take into consideration ambient temperature, name plate rating, design fundamentals, longtime emergency.
If they went unnoticed or unattended will results into a failure. Problem using retirements is that the transformer has not actually failed. New niyantra 20 distribution transformer fuse failure detection and information passing system by shankar. Asset criticality modelling in electricity distribution. This computational tool is applied to assist the management in about 61. Save this instruction sheet for future use of the product. Minimize the failures of distribution transformer seminar report pdf ppt download abstract. In order to analyze the transformer and compose a fault tree the transformer has been divided into di. Figure 1 is a scatter plot, or sometimes referred to as an fn curve. An overall view of the economic impact of a transformer failure and what can be done to reduce the risk, including. Distribution transformers always have the potential for eventful failure. The top 3 reasons for transformer failures machine design. New niyantra 20 distribution transformer fuse failure.
Complete selfprotection technolgy to minimize the failures of distribution transformer. For investigation purpose, we accept ieee standard c57. Rootcause analysis of transformer failure scenario at power. Internal fault detection in distribution transformers. They provide the link between the distribution network and customers, be they industries, communities or the infrastructure. Distribution transformer is an essential link in the distribution system. Some of the most commonly occurring failures of the transformer and their causes are listed below. The software gives the corresponding reading about the present health of distribution transformer and thus the performance can.
New hi parameters, an age distribution and logistic regression model were determined, enabling a higher accuracy in predicting failure events and can therefore be utilized in various asset management initiatives and risk mitigation. For the 3311kv transformer assumed failure rate fr was 1. Distribution transformer failures follow a bathtub curve. On the development of power transformer failure models. A transformer replacement decision method based on.
A schematic drawing of a singlephase distribution transformer appears in fig. A distribution transformer s function is straightforward. Estimate the lifetime probability distribution for each group of transformers from the available lifetime data. Troubleshooting transformer in power substation and. A transformer withdrawn due to being in a poor condition can be considered as a potential failure. A statistical approach to processing power transformer failure data conference paper pdf available january 2007 with 1,282 reads how we measure reads.
A statistical approach to processing power transformer. Receiving, handling, and storage 3 21 receiving immediately upon receipt of the equipment, and before putting it into service, inspect the transformer for any damage that may have occurred during shipment or storage. Prediction of remaining life of power transformers based. Premature failure of distribution transformers a case study. Troubleshooting transformer in power substation and detailed.
Transformer fuse operations are the most common equipment failure on distribution systems, comprising as much as 40% in one study 4. Pdf causes of transformer failures and diagnostic methods. Other causes of distribution transformer failure modes can be the result of a grounded core or core clamping structures such as throughbolts that develop shorts. Unit 14 transformers objectives after studying this unit, the student will be able to state the purpose of a transformer. In addition, impedance values of each transformer must be within 7. The probability density function pdf is shown in 1, where. Complete selfprotection technolgy to minimize the failures of. By changing the shape parameter and scale parameter, it can be used to depicted the equipment failure rate tendency at dif. Practical approach for detection of failure of distribution. Simplified transformer overloading guide lines take into consideration ambient temperature, name plate.
By changing the shape parameter and scale parameter, it can. Rootcause analysis of transformer failure scenario at. Difference between power transformer and distribution. These result in a shorted turn the core and produce high currents which are often detected by dissolved gas analysis. Effect of climate change on transformers loading conditions.
It is thus very important to avoid transformer failure. Guides for minimizing transformer noise proper installation of the transformer is required since a quiet transformer can develop objectionable sound levels. The various types of transformer shown in the figure above are explained in detail below. Failure of distribution transformers causes capital loss and loss of revenue to the nation. Basics, maintenance, and diagnostics vii contents continued page 4. The high rate of failure of secondary distribution transformer in power systems may perhaps be described as 0ne of the tragedies of distribution system management of present times especially in developing countries like india. The fault trees for the transformer is a result of discussions within the rcam group, ekc2, discussions with experts on transformers and a literature study. When paralleling three phase transformers the same precautions must be. A distribution transformer or service transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. Failure is when the transformer was scrapped after the fault nonrepairable, catastrophic failure is when either an explosion or fire occurred. An analysis of transformer failures, part 2 causes.
776 823 1452 71 501 1053 1386 117 1226 149 1279 1347 625 1020 956 789 234 379 980 1423 1344 365 1038 659 1188 922 1344 1063 1012 974 1075 1472 956 992 1154 1115 1338 778 1121 540 1162 773 485 801